Information Name: | Dry-type transformers |
Published: | 2015-05-13 |
Validity: | 15895 |
Specifications: | Customized |
Quantity: | 1895.00 |
Price Description: | |
Detailed Product Description: | ⑴ ⑵ solid insulation encapsulated windings not encapsulated coil winding two windings, the higher voltage is high voltage winding, low voltage winding is the relative position of high and low voltage windings, the high pressure can be divided into concentric overlapping concentric Winding simple, easy manufacturing, we are using this configuration mode. Overlapping style, mainly for special transformers. Features: 1. Safety, fire, pollution, can be run directly on the load center; 2. the use of advanced technology, high mechanical strength, resistance to short-circuit capability, partial discharge, thermal stability, high reliability, service life long; 3. low loss, low noise, energy-saving effect, maintenance-free; 4. Good heat dissipation, high overload capability, forced air cooling can increase capacity when running; 5. Good moisture resistance, adapt to high humidity and other harsh environments running; 6. dry-type transformers can be equipped temperature detection and protection systems. Intelligent signal temperature control system can automatically detect and touring show three-phase winding their operating temperature, can automatically start and stop the fan, and alarm, trip settings and other functions; 7. small size, light weight, small footprint, low installation costs. 8. Product Model: SC (B) 10-30 / 10 9. Brand: Adams Sutton core quality cold-rolled grain-oriented silicon steel, silicon steel core 45-degree miter joints, along the magnetic flux silicon joint direction by windings form ⑴ ⑵ wound epoxy resin plus quartz sand filling pouring ⑶ glass fiber reinforced epoxy resin cast (ie thin insulation) ⑷ multi-strand glass fiber impregnated with epoxy resin wound (generally use 3, because it can effectively prevent cracking of casting resin, improve equipment reliability) high voltage winding generally cylindrical multi-layer or multi-segmented structure generally use low voltage winding or foil layered structure ⒈ open type. is A common form of the body of their direct contact with the atmosphere, adapted to the relatively dry and clean room, (ambient temperature of 20 degrees, relative humidity should not exceed 85%), generally from the cold air and air-cooled two cooling way. ⒉ enclosed. is living in a closed shell, not in direct contact with the atmosphere. (due to seal poor heat dissipation is mainly used for mine it belongs to the explosion-proof) ⒊ pouring ceremony. with epoxy or Other cast resin as the main insulation, simple structure, small volume, suitable for small capacity transformers. Features Construction temperature control safe operation of the transformer and its dry-life system depends largely on the transformer winding insulation safety reliability. Cooling dry type transformer cooling mode is divided into natural air cooling (AN) and forced air cooling (AF). When natural air cooling, the transformer can be long-term continuous operation at nominal capacity. When forced air cooling, transformer output capacity can be increased by 50%. Suitable for intermittent overload operation, accident or emergency overload operation; due to overload load loss and impedance voltage larger increase in the non-state economy, it should not make it in a long time continuous overload operation. Technical parameters, frequency of use: 50 / 60HZ; 2, load current: <4%; 3, compressive strength: 2000V / min without breakdown; testing equipment: YZ1802 pressure tester (20mA); 4, insulation class : F grade (special grades can be customized); 5, the insulation resistance: ≥2M ohm test equipment: ZC25B a 4 megameter <1000 V); 6, Connection: Y / Y, △ / Y0, Yo / △, auto formula (optional); 7, the coil allowable temperature rise: I00K; 8, Cooling: natural air cooling or temperature automatic heat; 9 and noise factor: ≤30dB the general direction of future development (1) energy-saving and low noise: Low loss silicon-depth, step ladder laminated core seams, foil winding structure, noise studies, environmental requirements, computer optimized design of new materials, new processes, new technology introduction and development will enable future dry-type transformers more energy, more quiet. However, simply relying on input materials to reduce iron loss or copper loss, we think is desirable. (2) High reliability: electrical products, especially the transformer, its operational reliability is particularly important. In the electromagnetic theory and computation, wave process, casting process, hot temperature, partial discharge mechanism, quality assurance system, reliability engineering and other aspects of a lot of basic research, actively reliability certification, and further improve the reliability of dry-type transformers, The people's unremitting pursuit. (3) the environmental characteristics of certification: based on European standards HD464 conduct weather dry-type transformers (C0, C1, C2), resistance to environmental (E0, E1, E2), refractory study (F0, F1, F2) properties and certification. (4) Large capacity: 2,500KVA distribution transformer capacity is usually less. With the city electricity load increasing, urban and regional substations more in-depth urban centers, residential areas, factories, mines and other large and medium load centers, 35KV high-capacity regional supply dry-type power transformer will be widely applied. Shunte has produced nearly ten 35KV 16,000 / 24,000KVA large capacity becomes dry. (5) Multi-functional and intelligent: with only from a single transformer substation functions, combined with the versatility of forced air-cooled, protective housing, power measurement, computer interface, enclosed bus, and other low-voltage side outlet Transformer development; introducing TTU intelligent interface with data processing, state control, status display and other functions, so that the transformer has become a multi-functional intelligent, ready to run in the best state of the electrical equipment. (6) multi-field development: mainly from a distribution transformer, excitation transformer to power plants, transformer plant, rail traction rectifier transformer, electric furnace large current change, nuclear power plant, marine, oil platforms with other special-purpose transformers and more sectors. In recent years SUNTEN has developed and mass production of these particular products in many fields. (7) multi-material, multi-species: In China, the epoxy resin vacuum casting dry-type transformers occupy a dominant market. Work Environment O - 4O ℃, relative humidity <80% Altitude: not more than 2500 meters. Avoid being rain, humidity, high temperature, heat or direct sunlight. Its cooling vents and the surrounding objects should be not less than 40cm distance. Work to prevent corrosive liquids, or gases, dust, conductive fibers or metal fines more places. Prevent vibration or electromagnetic interference in place. Avoid prolonged inverted storage and transport, can not be subject to strong impact. Parameter Model Phase Dimensions (mm) Weight (Kg) LWH BGS-3 3 350 280 380 30 BGS-6 3 400 280 400 35 BGS-10 3 400 280 400 50 BGS-15 3 450 300 450 65 BGS -20 3 450 300 450 85 BGS-25 3 450 350 450 90 BGS-30 3 450 350 450 110 BGS-35 3 550 360 550 120 BGS-40 3 550 360 550 130 BGS-45 3 550 400 550 140 BGS-50 3 550 400 550 150 BGS-60 3 600 450 660 175 BGS-80 3 600 450 660 200 BGS-100 3 710 520 710 235 BGS-150 3 710 520 710 250 BGS-200 3 800 600 810 300 BGS-250 3 800 600 810 330 BGS-300 3 850 650 900 380 BGS-350 3 950 700 1000 430 BGS-400 3 950 700 1000 480 BGS-450 3 1100 800 1400 500 BGS-500 3 1500 850 1400 660 1 wiring shorted transformers "input" and "output" megger test terminals with ground insulation resistance. When 1000V megger, resistance is greater than 2M ohms. 2, transformer input and output power wiring line section shall meet the requirements of its current size; in accordance with 2-2.5A / min2 current density configuration is appropriate. 3, input, output three-phase power line transformer wiring board bus color should be yellow, green, red, respectively, then A-phase, B-phase, C phase, the zero line and the transformer voltage regulator should be neutral zero line phase, grounding lines, transformers the center of the housing and connected to the transformer. Usually we say that ground zero lines are drawn from the transformer neutral point. (Eg transformer cabinet and the cabinet should be connected to the corresponding earth sign). Check the input and output lines to confirm correct. 4, the first no-load electricity, observe the test input and output voltages to meet the requirements. While observing whether there is abnormal sound inside the machine, sparking, odors and other non-normal, if unusual, immediately disconnect the input power. 5, when the load test is complete and functioning before the access load. |
Admin>>>
You are the 4774 visitor
Copyright © GuangDong ICP No. 10089450, Electrical Technology Co., Ltd. on the Hai Shumin All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 4774 visitor
Copyright © GuangDong ICP No. 10089450, Electrical Technology Co., Ltd. on the Hai Shumin All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility